75580G-M79580G-Binstruction booklet gas hobGB
10The burnersz The burner caps and crowns can be removed for cleaning.z Wash the burners taps and crowns using hot soapy water, and remove marks with
11Something Not Working?If the hob is not working correctly, please carry out the following checks before contactingyour local Service Force Centre.
12OVERALL DIMENSIONS Glass cooktop models:Width: 740 mmDepth: 510 mmStainless steel models:Width: 745 mmDepth: 515 mmCUT OUT DIMENSIONS Width: 560 mmD
13Gas burnersNATURAL GAS20 mbarVALUE =37.78 MJ/m3Ws - 50.7 MJ/ m3TYPE OF GASLPG GAS28-30/37 mbarVALUE =49.92 MJ/KgBURNER SEMI-RAPID AUXILIARY TRIPLECR
14Important Safety RequirementsThis hob must be installed in accordance with the Gas Safety (Installation and Use)Regulations (Current Edition) and th
15IMPORTANTThis hob must be installed by a competent person to the relevant Gas Standards.Any gas installation must be carried out by a registered com
16LocationThe hob may be located in a kitchen, akitchen/diner or bed sitting room, but notin a bathroom, shower room or garage.Ensure that there is a
17Fitting the Hob into the WorktopCarry out the building in of the hob as follows:1) Remove the pan supports, the burners caps andcrowns and turn the
182Dimensions are given in mm.3Building over a cupboard or drawerIf the hob is to be installed above a cupboard or drawer it will be necessary to fit
19Electrical ConnectionsAny electrical work required to install this hob should be carried out by a qualifiedelectrician or competent person, in accor
2Thank you for choosing one of our high-quality products.To ensure optimal and regular performance of your appliance please read thisinstructionmanual
20Permanent ConnectionIn the case of a permanent connection, it is necessary that you install a double pole switchbetween the hob and the electricity
21Fault FindingPreliminary Electrical Systems CheckSTARTIsolate applianceand carry out:A: Earth Continuitycheck. Has inlet fuse blown?Carry out:C: Pol
22A. EARTH CONTINUITY CHECKAppliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjustzero if necessary.— Test leads from
23Check gas supply atburnerIgnition System / Gas IgnitionYESCheck plug top fuse andreplace if necessaryCheck polarity and earthcontinuity of supply po
24CommissioningWhen the hob has been fully installed it will be necessary to check the minimumflame setting. To do this, follow the procedure below.1)
25IMPORTANTThe replacement/conversion from natural gas to LPG should only be undertakenby a competent person.It is important to note that this model i
26Standard guarantee conditionsWe, AEG-Electrolux, undertake that if within 12 months of the date of the purchasethis AEG-Electrolux appliance or any
27Service and Spare PartsIn the event of your appliance requiring service, or if you wish to purchase spareparts, please contact your local Service Fo
28This appliance is guaranteed by Electrolux in each of the countries listed at the back of this usermanual, for the period specified in the appliance
3Important Safety Information... 4Descriptio
39712-5701 03/09 R.A Subject to change without notice
4Installation• This appliance must be installed andserviced by a competent person as statedin the Gas Safety (Installation and Use)Regulations Current
5cause an accident by tipping or spillage.• Never leave the hob unattended whencooking with oil and fats.• Never use plastic or aluminium foil disheso
6Description of the hob412225678391. Hob Top2. Semi-rapid Burners3. Auxiliary Burner4. Triple Crown Burner5. Control knob for left burner (triple crow
7OperationHob burner control knobsThe symbols on the knobs mean:= no gas supply = maximum gas supply = minimum gas supplyFor easier lighting
8Once the hob has been installed, it is important to remove any protective materials,which were put on in the factory.Using the Wok StandA wok stand i
9Mainteinance and CleaningThe Hob Topz Regularly wipe over the hob top using a soft cloth well wrung out in warm water towhich a little wasing up liqu